MSR error. Extended error code §

Hi!

I have problems with Wincor Nixdorf MSR. It works fine in Wincor Nixdorf config tool. When I try to use it (for log on) on my cash registry OPOS fires an error event. The extended error code is OPOS_EMSR_START ("start sentinel error" according to the manual).

I have enabled trace capability. Here is an extract from the log file: SO MSR MSRProc: correct card detected status: track1 = -1, track2 = 31, track3 = -1 data: track1 track2 = 000000000000200201650000001234? track3 SO MSR MSRProc: fire error event, ErrorReportingType = 0 SO_MSR/WN_TA.16(183625656): { Fire_ErrorEvent(114, 201, 3, 13) SO MSR MSRProc: 0 00000078 c0430001 SO MSR MSRProc: 0 0000000d 001c0001 SO_MSR/WN_TA.16(183630140): SetPropertyNumber(Index=2, Value=1=0x00000001) : returns OPOS_SUCCESS(0) pResponse_is_12_} SO MSR MSRProc: error event response = 12

OPOS seems to be able to read track2 (the data is correct) but then it fires an error event. I cannot understand why.

Best regards, Anatoly

Reply to
anatoly71
Loading thread data ...