Aug 23, 2005 5 Replies

We have four registers that we have been running for two years with RMS. Recently we started to use the 4th one again after a long time and everyother transaction activates a Write Error. None of the other registers have the problems including one that hasn't been used for the same amount of time as the fourth and there have been no significant changes to any computer besides microsoft updates for XP. Help Please


They are all on the same version. They are using the same Database. The are using the same router. I believe they are running service pack 2. The strangest thing is that it is only that one register the other three have no problems.

The error reads Write Error The System Does Not Recognize the Command

Are all registers on the same RMS version. ? What is the version # ? Have you upgraded to Service Pack 2 or 3 on all machines ?

Mihir Diviasoft, Inc

formatting link

Can you let me know the exact error ?

Mihir

I think that you are getting this error because of changes made without doing a Z-report on the workstation. Make a list of all open batches in the SO Manager. Than you need to do a Z-report on all machines and closed any open batches in the system. (Once a batch is closed it will creat another open batch which you can leave open) Than restart the machine and you should be ok.

Let me know if you still have a problem.

Mihir Diviasoft, Inc snipped-for-privacy@diviasoft.com